Case Report - Interventional Cardiology (2016) Volume 8, Issue 3

Sub-acute anterior myocardial infarction due to the discontinuation of warfarin in a patient with aortic valve prosthesis: what is the best treatment

Corresponding Author:
Antonio L Aguilar-Shea
Centro de Salud Puerta de Madrid, Spain
Tel: +34918806699
E-mail: antonio.aguilar@salud.madrid.org

Submitted: 23 May 2015; Accepted: 30 June 2016; Published online: 30 June 2016

Abstract

Acute myocardial infarction (MI) is a common entity in patients due to the atherosclerotic plaque rupture or coronary embolism. We present a patient who had a mechanical aortic valve and was admitted to the hospital for a sub-acute anterior ST elevation myocardial infarction due to the discontinuation of warfarin. In case of persistent thrombus formation despite aggressive antithrombotic and anticoagulant therapy, thrombus aspiration, angioplasty and stenting should be preferred rather than conservative approach.

Acute myocardial infarction (MI) is a common entity in patients due to the atherosclerotic plaque rupture. But there are other susp10cious etiologic reasons that lead to coronary embolism such as intra-cardiac prosthesis, infective endocarditis, mural thrombus or a cardiac tumor [1-7]. Even if the patient did not use warfarin, the real reason for acute myocardial infarction whether embolism or atherosclerotic plaque ruptures should be revealed in order to decide optimal treatment option. Intravascular ultrasonography and optical coherence computed tomography are very useful to diagnosis so which treatment is the best; thrombolysis, angioplasty or stenting. Previous cases of coronary emboli in association with prosthetic mechanical valves have been reported previously but the treatment is controversial [8-16]. We present a patient who had a mechanical aortic valve and was admitted to the hospital for a sub-acute anterior ST elevation myocardial infarction due to the discontinuation of warfarin.

Case

A 58-year- old male presented with severe retrosternal chest and back pain radiates to his left arm for 20 hours was admitted to our coronary care unit. His symptoms were resolved on admission. He had previous mechanical aortic valve implantation nine years earlier because of a rheumatic aortic valve. The patient did not have a history of traditional cardiovascular risk factors except smoking (1 pack a day) and hypertension. No other comorbidities are present. His familial medical history is otherwise unremarkable. Pulse rate was 68/bpm, regular, arterial blood pressure was 110/70 mmHg, lungs were clear breath rate was 18/pm, no murmur on physical examination. Systolic ejection murmur grade 2/6 on the second right parasternal space and a mechanical valve click was heard with the cardiac auscultation. The electrocardiography (ECG) revealed ST-segment elevation in the precordial leads consistent with sub-acute anterior myocardial infarction (MI); ST segment elevation in V1-6, T inversions and pathological Q waves on admission (Figure 1). There was significant elevation of the cardiac markers (troponin T level of 8022 ng/ml and creatinine kinase-MB level of 340 U/L). The patient’s INR level was 1.34 reflecting an unprotected and prothrombotic state. Physical findings were not remarkable. The patient was diagnosed to have a sub-acute anterior ST-elevation myocardial infarction (STEMI). Left ventricular ejection fraction(LVEF) was 30% and severe akinesia of the anterior and apical wall of the left ventricle was detected on transthoracic echocardiography so we started the dual anti-platelet therapy (aspirin 300 mg +180 mg ticagrelor as for loading dosage), and unfractionated heparin infusion. After that, the patient was transferred to the catheter laboratory and coronary angiography (CAG) showed total occlusion of the proximal part of the left anterior descending artery (LAD) (Figure 2). There were no significant stenosis on the right coronary artery and circumflex artery. We advanced a 0.014 inch floppy guide wire and passed through the lesion, we attempted to aspirate the thrombus three times by using intracoronary catheter aspiration was but was not successful. The occlusion was inflated with 1.5 × 15 mm and 2.5 × 15 mm balloons (Figure 3) but they were also unsuccessful due to the severe residue coronary thrombus (Figures 4-7). A drug eluting stent (3.0 × 15 mm) was inserted and TIMI flow was so good but distal embolism developed, which completely not obstructed the lumen (Figure 8). The patient was transferred to the coronary care unit and intravenous glycoprotein IIbIIIa inhibitor (abciximab) plus heparin were also started for 24 hours. Control CAG showed the flow was good but there was no thrombus formation in the LAD. The ECG was improved. The patient was discharged 7 days later on acetylsalicylic acid, and beta- blockers, and angiotensin-converting enzyme inhibitor therapy under maintenance of warfarin (with an INR value of 3-3.5).

interventional-cardiology-ECG-during-admission

Figure 1: The ECG during admission.

interventional-cardiology-angiographic-images

Figure 2: The angiographic images of the patient with total occlusion of the LAD.

interventional-cardiology-balloon-inflation

Figure 3: The angiographic images of the patient during balloon inflation.

interventional-cardiology-after-balloon-inflation

Figure 4: The angiographic images of the patient after first balloon inflation.

interventional-cardiology-cranial-projection

Figure 5: The angiographic images of the patient after second balloon inflation with cranial projection.

interventional-cardiology-residue-thrombus

Figure 6: The angiographic images of the patient after second balloon inflation and residue thrombus with cranial projection.

interventional-cardiology-lateral-projection

Figure 7: The angiographic images of the patient after second balloon inflation with lateral projection.

interventional-cardiology-stent-implantation

Figure 8: The angiographic images of the patient during stent implantation.

Discussion

There are many solutions for treatment of coronary embolism. One of them is thrombus aspiration but it may not be enough to track thrombus from coronary vasculature despite several trials with aspiration catheter. The other one is only percutaneous coronary angioplasty without stenting but it may not also obtain optimal angiographic result and TIMI flow. Another choice is stenting in case of all failed interventions. High dosage anti aggregant and anticoagulant therapy are also possible solutions. In case of high thrombus burden causes total occlusion of the coronary vessels, aggressive antithrombotic treatment is feasible in case of low bleeding risk as in our case. So, in case of persistent thrombus formation despite aggressive antithrombotic and anticoagulant therapy, thrombus aspiration, angioplasty and stenting should be preferred rather than conservative approach. A prosthetic mechanical valve requires the use of long-term conventional anticoagulation therapy with warfarin and it is important for the doctors to be lack of awareness of medication of patient who carries significant thromboembolic risk. The choice of treatment should be based on individual decisions and should be set depending on the clinical and comorbid condition of the patient.

References

Awards Nomination 20+ Million Readerbase

Journal Metrics:

Impact Factor 1.34
Scimago Journal Rank (SJR) 123
SJR Total Cites 15
Source Normalized Impact per Paper (SNIP) 0.144
h-index (2023) 12
PubMed NLM ID:  10148499
Google Scholar h5 index: 6
Iindex Copernicus Value: 105.52


Google Scholar citation report
Citations : 1400

Interventional Cardiology received 1400 citations as per Google Scholar report


Interventional Cardiology peer review process verified at publons

Indexed In

flyer